Standards:
IEC51, IEC61010-1, VDE410, BS89, UL94, NE60051, DIN43780
Cases: Temperature influence:
All cases at least dust and splash water-proof.
All cases are made of strengthened self-extingushing PPO
With a high hit-resistance and a maximum electric isolation
All instruments operate trouble-free at room temperature ranging from -25¡æ to + 40¡æ.
The Max. Voltage to earth Voltmeter-The upper range voltage (full scale deflention)
Ammeter-The Voltage of the main power supply.
The meter used shall be keep cleaning. The user shall be made aware that, if the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired.
Accuracy class:
AC, DC Voltmeters and Ammeters comply with the accuracy class 1.5.
The power meters comply with accuracy class 1.5.
The frequency meters comply with accuracy class1.0.
The maximum-demand meters comply with accuracy class 3.0.
The power factor meters and synchroscope meter comply with accuracy class 2.5.
Insulation test:Mounting angle:
The insulation test is carried out at a voltage of 2KV, 50Hz 1 min and applies for instruments with the full scale deflection up to 650V. Other standards comply with IEC61010-1.The instruments are calibrated for vertical mounting, unless other positions such as horizontal or inclined at any specified angle to the horizon. can be provided upon request (in this case, specify angle of inclination, please) The accuracy class refers to the specified mounting angle only.
Singals for ldentification of the lnstruments Tech Characteristics:
Electronic device in a measure circuit
Rectifier (instrument with AC input)
Shunt
Additional resistor
Positive terminal
Negative terminal
Class lndex
DC
AC
DC & AC
Testing voltage higher than 2000V
Vertical mounting
Inclined mounting (for example 50¡ã)
Moving coil for instruments
Moving lron for instruments
Bimetal instrument
Vibrating reeds instruments
 
Home
Products
Meter & Current Transformer
LOW VOLTAGE CURRENT TRANSFORMERS
MSQ CURRENT TRANSFORMERS
DP CURRENT TRANSFORMERS
DX CURRENT TRANSFORMERS
RED & EMC CURRENT TRANSFORMERS
MR CURRENT TRANSFORMERS
Z.E.T CURRENT TRANSFORMER
DH TOROIDAL TRANSFORMER
Tdgc Tsgc Voltage Regulator
Machine Tool Control Transformer
PANEL METER
DW26 series rotary switches
Selection of typical contact diagrams
DW26GS series Pad-lock type switches
DW30 ROTARY switches SERIES
Dimensions
DT862-4 Series Three-phase KWH Meter
DD282 Single-Phase Kwh Meter
DTS523 Three Phase Four Wire Active Electrical Meter
NSQ CURRENT TRANSFORMERS
CDS CURRENT TRANSFORMERS
D363 D364 CURRENT TRANSFORMERS
OTHER CURRENT TRANSFORMER
SVC Fully Automatic Voltage Regulator
Ups Uninterruptable Power Supply
Summary
Escutcheon plate and handle
Terminal Block
DDS523 Single-phase KWH Meter
ddsy523 Series Electronic Single-phase kwh Meter With A Function Of Advance Payment
DD17 Series Three-Phase kwh Meter
DM CURRENT TRANSFORMERS
MES CURRENT TRANSFORMERS
RCT CURRENT TRANSFORMERS
PR CURRENT TRANSFORMERS
SFT CURRENT TRANSFORMERS
E TYPE POWER TRANSFORMER
AVR Fully Automatic Voltage Regulator
Connection diagram
DW26S Key-lock type switches
Specification and Way of order
DD862 dd862a single-phase KWH meter
DD284 Series Three-phase kwh meter
Dtsy523 (ic Card) Three Phase Electronic Prepayment Kwh Meter
DT8 Series Three-Phase kwh Meter
Mini Circuit Breaker
Earth Leakage Circuit Breaker
Moulded Case Circuit Breaker
Thermal Relay
Fuse
Switch
Contactor
Pushbutton
Relay
Socket Series
Electrical Accessory
Distribution Box
Instruments
Lamp & Socket Series