Specification and Way of order
Specification
Type
DW30-20
DW30-32
DW30-40
DW30-63
DW30-80
DW30-100
Rated insulation voltage Ui
V
DW30-20
DW30-32
DW30-40
DW30-63
DW30-80
DW30-100
Rated thermal current Ith
A
DW30-20
DW30-32
DW30-40
DW30-63
DW30-80
DW30-100
Rated working current le
AC-23A
A
15
22
30
43
57
70
AC-3
A
11
15
22
36
43
57
Rated working voltage Ue
V
240 260
240 440
240 440
240 440
240 440
240 440
Power P
AC-23A
kW

4 7.5

5.5 11
7.5 15
11 22
18.5 30
22 37
AC-3
kW
3 5.5
4 7.5
7.5 11
11 18.5
15 22
18.5 30
Rated short current lcw/s
A
180
264
360
516
684
840
Rated limit current
Type of fuse
RL6-25/20
RL6-63/35
RL6-63/50
RL6-63/63
RL6-100/80
RL6-100/100
Rated short current
kA
10
10
25
25
25
25
Way of order
When you order our DW30 series, We need you data as following
1. Rated working current, for example: DW30-20;
2. Accessorial code, please write it orderly
1) Number of poles, for example: 3P;
2) Do you need adding contacts: 0 No order it, 1 Order it;
3) Do you need neutral terminal: 0 No order it, 1 Order it;
4) Do you need earthing terminal: 0 No order it, 1 Order it;
5) Way of installation:
6) Type of box: 0 Not order it, 1 Order it
3. Other accessorial code, please write it orderly
1) Type of Escutcheon plate:
2) Do you need Escutcheon plate with airproof: 0 Not order it, 1 Order it
3) Colour of bottom plate:4) Character letter: 1 Note letter; 2 Chinese letter; 3 Special sign
5) Code of handle: R or K or I
For example:
If you order 40A/3P with adding contacts and earthing terminal and Escutcheon plate without neutral terminal and plastic box.
You must write: DW30-40/310120
If you want to order 32A/3 with Doorlock safety switch
You must write: DW30-32/300030
If you want to order 40A/3 with adding contacts, earthing terminal, Escutcheon plate, M2 plate, plate with airproof, Yellow, Chinese letter, K handle; without neutral terminal and plastic box.
You must write: DW30-40/310120.2123K
 
Home
Products
Meter & Current Transformer
LOW VOLTAGE CURRENT TRANSFORMERS
MSQ CURRENT TRANSFORMERS
DP CURRENT TRANSFORMERS
DX CURRENT TRANSFORMERS
RED & EMC CURRENT TRANSFORMERS
MR CURRENT TRANSFORMERS
Z.E.T CURRENT TRANSFORMER
DH TOROIDAL TRANSFORMER
Tdgc Tsgc Voltage Regulator
Machine Tool Control Transformer
PANEL METER
DW26 series rotary switches
Selection of typical contact diagrams
DW26GS series Pad-lock type switches
DW30 ROTARY switches SERIES
Dimensions
DT862-4 Series Three-phase KWH Meter
DD282 Single-Phase Kwh Meter
DTS523 Three Phase Four Wire Active Electrical Meter
NSQ CURRENT TRANSFORMERS
CDS CURRENT TRANSFORMERS
D363 D364 CURRENT TRANSFORMERS
OTHER CURRENT TRANSFORMER
SVC Fully Automatic Voltage Regulator
Ups Uninterruptable Power Supply
Summary
Escutcheon plate and handle
Terminal Block
DDS523 Single-phase KWH Meter
ddsy523 Series Electronic Single-phase kwh Meter With A Function Of Advance Payment
DD17 Series Three-Phase kwh Meter
DM CURRENT TRANSFORMERS
MES CURRENT TRANSFORMERS
RCT CURRENT TRANSFORMERS
PR CURRENT TRANSFORMERS
SFT CURRENT TRANSFORMERS
E TYPE POWER TRANSFORMER
AVR Fully Automatic Voltage Regulator
Connection diagram
DW26S Key-lock type switches
Specification and Way of order
DD862 dd862a single-phase KWH meter
DD284 Series Three-phase kwh meter
Dtsy523 (ic Card) Three Phase Electronic Prepayment Kwh Meter
DT8 Series Three-Phase kwh Meter
Mini Circuit Breaker
Earth Leakage Circuit Breaker
Moulded Case Circuit Breaker
Thermal Relay
Fuse
Switch
Contactor
Pushbutton
Relay
Socket Series
Electrical Accessory
Distribution Box
Instruments
Lamp & Socket Series