LOW VOLTAGE CURRENT TRANSFORMERS
General: Measuring current transformers:
Current transformer is a very useful device because it converts high AC current to small easily manageable value.Current transformers consist of primary winding, secondary winding, magnetic core and insulated body. If current transformers have no bus bar, they are manufactured without primary winding. Instead of this, it is possible to constitute primary winding by passing conductor or busbar inside toroidal core of transformer.
Dixsen current transformers are produced according to IEC IEC44-1. Furthermore, the secondary terminals are under a transparent seable cover. Low voltage current transformers are manufactured as of two types for measuring and protection.
Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instrument, relay, watt-hour meter (kW meter), these type of current transformers are mainly used 0.5 and 1 class to transfer the current from highest rated current to rated secondary current.
Protection current transformers:
Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used class 3. (Customer supplied when required.)
Current errors and phase shift in measuring current transformer:
Accuracy
Class
permissible ratio error ”Ąat
Various percentage of rated
secondary current
”Ąphase shift in various percentages of rated secondary current
Minute
Centiradian
%5
%20
%100
%120
%5
%20
%100
%120
%5
%20
%100
%120
0,1
0,2
0,5
1,0
0,4
0,75
1,5
3,0
0,2
0,35
0,75
1,5
0,1
0,2
0,5
1,0
0,1
0,2
0,5
1,0
15
30
90
180
8
15
45
90
5
10
30
60
5
10
30
60
0,45
0,9
2,7
5,4
0,24
0,45
1,35
2,7
0,15
0,3
0,9
1,8
0,15
0,3
0,9
1,8
Current errors and phase shift in protection current transformer:(Fault conditions)
Accuracy
Class
permissible ratio error ”Ąat
Various percentage of rated
secondary current
”Ąphase shift in various percentages of rated secondary current
Compound eror for
rated current %
Minute
Centiradian
5P
10P
”Ą1
”Ą3
”Ą60
--
”Ą60
--
5
10
Current errors and phase shift in measuring current transformer:
Accuracy
Class
”ĄPercentage ratio of current error for rated current percentage
%50
%120
3
5
3
5
3
5
 
 
Home
Products
Meter & Current Transformer
LOW VOLTAGE CURRENT TRANSFORMERS
MSQ CURRENT TRANSFORMERS
DP CURRENT TRANSFORMERS
DX CURRENT TRANSFORMERS
RED & EMC CURRENT TRANSFORMERS
MR CURRENT TRANSFORMERS
Z.E.T CURRENT TRANSFORMER
DH TOROIDAL TRANSFORMER
Tdgc Tsgc Voltage Regulator
Machine Tool Control Transformer
PANEL METER
DW26 series rotary switches
Selection of typical contact diagrams
DW26GS series Pad-lock type switches
DW30 ROTARY switches SERIES
Dimensions
DT862-4 Series Three-phase KWH Meter
DD282 Single-Phase Kwh Meter
DTS523 Three Phase Four Wire Active Electrical Meter
NSQ CURRENT TRANSFORMERS
CDS CURRENT TRANSFORMERS
D363 D364 CURRENT TRANSFORMERS
OTHER CURRENT TRANSFORMER
SVC Fully Automatic Voltage Regulator
Ups Uninterruptable Power Supply
Summary
Escutcheon plate and handle
Terminal Block
DDS523 Single-phase KWH Meter
ddsy523 Series Electronic Single-phase kwh Meter With A Function Of Advance Payment
DD17 Series Three-Phase kwh Meter
DM CURRENT TRANSFORMERS
MES CURRENT TRANSFORMERS
RCT CURRENT TRANSFORMERS
PR CURRENT TRANSFORMERS
SFT CURRENT TRANSFORMERS
E TYPE POWER TRANSFORMER
AVR Fully Automatic Voltage Regulator
Connection diagram
DW26S Key-lock type switches
Specification and Way of order
DD862 dd862a single-phase KWH meter
DD284 Series Three-phase kwh meter
Dtsy523 (ic Card) Three Phase Electronic Prepayment Kwh Meter
DT8 Series Three-Phase kwh Meter
Mini Circuit Breaker
Earth Leakage Circuit Breaker
Moulded Case Circuit Breaker
Thermal Relay
Fuse
Switch
Contactor
Pushbutton
Relay
Socket Series
Electrical Accessory
Distribution Box
Instruments
Lamp & Socket Series